JE-H(ST)H BMK  ...Bd E90 | Halogen-Free and Flame Retardant Installation Cables for Industrial Electronics with Circuit Integrity of 90 Minutes

 
 

Item descriptions

Application: Suitable for fixed installations in telecommunication. They are to be used in locations with fire hazard and where insulation integrity of at least 180 minutes and circuit integrity of at least 90 minutes are required.
Construction:
1.....solid bare copper
2.....core covering with glassfibre tape (MICA)
3.....core insulation of halogen-free, cross-linked polymer, Cores twisted to          pairs and four twisted pairs in a bundle, bundle identification by Number          characteristic helix (Z) or ring mark on core insulation (Si)
4.....layer of plastic foil
5.....static screen of plastic laminated aluminium foil with          a solid tinned drain wire 0,8 mm
6.....outer sheath of halogen-free polymer (HM 2)          red with the marking 'BRANDMELDEKABEL' (fire alarm cable)
Information: These cables fulfil the conditions of the tests to insulation integrity according to DIN VDE 0472-814/ 8.83 about 180 min. and IEC Public. 331 first edition 1970 to circuit integrity about 30 min. to DIN 4102-12 according to VDE 0100-710 and 0100-718.
Standards: DIN VDE 0815 (core identification) DIN EN 60228 class 1 (construction) DIN VDE 0207-24
Technical data:
Peak operating voltage [V] 225 Volt
Temperature range in motion -  5°C till +50°C
fixed -30°C till +70°C
Bending radius in motion x diameter 7,5
Flammability standard EN  50226-2-4 EN  60332-1 IEC 60332-3 Kat.C
Insulation resistance min. [MOhm/km] 100
Mutal capacitance [Ohm/km] 73,2
max. [nF/km] 120
Capacitance unbalance 100m max [pF] 200
Number of pairs and nominal conductor diameter (mm) Copper figure kg/km Insulation thickness mm Overall diameter appr.mm Calorific potential kWh / m Weight appr. kg / km
  2 x 2 x 0,8 24,00 1,0 12,8 0,56 177
  4 x 2 x 0,8 43,20 1,0 16,3 0,85 284
  8 x 2 x 0,8 81,60 1,2 20,3 1,33 447
12 x 2 x 0,8 120,96 1,2 23,9 1,84 615
16 x 2 x 0,8 159,36 1,4 26,6 2,22 756
20 x 2 x 0,8 197,76 1,4 29,4 2,72 921

Title: JE-H(ST)H E90 BMK

Download PDF Data sheet

TOP

Tesla kabeli d.o.o.
Industrijska 20, 10431 Sveta Nedelja, Hrvatska

OIB: 75321357467
MB: 4081340

OTP banka d.d. - Split HR6524070001100185687 | SWIFT OTPVHR2X
Nova hrvatska banka d.d. - Zagreb HR3625030071100101879 | SWIFT VBCRHR22
KentBank d.d. – Zagreb HR5341240031199011634 | SWIFT KENBHR22
Erste&Steiermärkische Bank d.d. - Zagreb HR5024020061100674424 | SWIFT ESBCHR22

Tesla kabeli d.o.o.
Batajnički drum 10. deo br. 1, 11080 Zemun, Srbija

PDV: RS108828595
PIB: 108828595
MB: 21075680

AIK banka A.D. - Beograd RS35105000000280701248 | SWIFT AIKBRS22
OTP banka - Srbija A.D. Novi Sad RS35325960170006817238/ SWIFT: OTPVRS22
ERSTE BANK - A.D. Novi Sad RS35340000001101229969 / SWIFT: GIBARS22